What are some requirements for a wound rotor induction motor speed control circuit?
What will be an ideal response?
The requirements for a wound rotor induction motor speed control circuit include:
1. The motor is to operate on a 480-volt three-phase power system, but the control system is to operate on 120 volts.
2. One stop button can stop the motor regardless of which speed has been selected.
3. The motor will have overload protection.
4. Three separate push buttons will select first, second, or third speed.
5. There will be a three-second time delay between accelerating from one speed to another.
6. If the motor is in operation and a higher speed is desired, it can be obtained by pushing the proper button. If the motor is operating and a lower speed is desired, the stop button must be pressed first.
You might also like to view...
Discuss the role and location of the grounding bus.
What will be an ideal response?
The purpose of an evaporator in the refrigeration cycle is to _____.
a. make sure no liquid gets into the compressor b. transfer heat from the air to the refrigerant c. transfer heat to the outdoors d. provide a pressure drop
What is auxiliary heat?
A) A separate system connected to the same ductwork B) Another heat source added to make up the difference between the heat pump capacity and the house load C) a heating system that is not really needed D) a heating system that operates using "green" alternative energy
Soft-drawn copper tubing typically comes in ____ ft rolls.
A. 25 B. 50 C. 75 D. 100