Explain why the usual dip tube failure reduces the volume of hot water available upon request.
What will be an ideal response?
Cold water will mix with the tank contents above the lowest level. The effect will be to
reduce the apparent capacity of the heater because the heated water is significantly
cooled by cold water dilution at the top of the water heater.