You are testing an energized solenoid in a series circuit using a voltmeter and identify the following circuit conditions:
Voltage measured from solenoid positive terminal to chassis ground:   12.6 V-DC
Voltage measured from solenoid negative terminal to chassis ground:  4.0 V-DC
Voltage dropped across solenoid positive to negative terminals: 8.5 volts
Where is the problem in the circuit likely to be found?

A. On the positive side of the load
B. On the negative side of the load
C. The load (solenoid)
D. No circuit problem based on this data


Answer: B