An 11-in. thick precast concrete curtain wall consists of a 3-in.-thick exterior layer of (normal-weight) concrete, 6-in.-thick interior layer of (normal-weight) concrete and a 2-in-thick XPS insulation sandwiched between the two concrete layers. What is the total R-value of the assembly, considering air-to-air heat transfer? ?-value of normal-weight concrete = 0.15; ?-value of XPS = 5.0
What will be an ideal response?
R-value of 3-in-thick concrete layer = (3)0.15 = 0.45
R-value of 2-in-thick XPS = (2)5.0 = 10.0
R-value of 6-in-thick concrete layer = (6)0.15 = 0.90
Rsi = 0.7
Rso = 0.2
You might also like to view...
Cuando se instalan piezas de capas de cemento super- puestas _____.
a. se instala el cemento antes de instalar la cubierta de tuberías b. se debe comenzar en la parte inferior de la pieza e ir trabajando hacia arriba c. se debe usar sólo cemento para altas temperaturas d. Ninguno de los anteriores.
What are the three types of starting relays used on single-phase hermetic motors?
What will be an ideal response?
Rabbits are used extensively to feed pets such as snakes.
Answer the following statement true (T) or false (F)
Before a container of a stored recycled refrigerant is used, the container must be checked for:
A) gross weight B) non-condensable gases C) moisture contamination D) DOT approval