Why is it incorrect to close the suction line service valve to test a compressor?
What will be an ideal response?
Closing the suction line service valve causes the compressor to pull a vacuum on itself. Compressors that are not designed to operate in a vacuum can arc out electrically if operated in a vacuum.
You might also like to view...
Technician A says that E3 injectors are better suited to multi-pulse injection because the injection pressure is not required to collapse within the EUI between injection pulses. Technician B says that at any time the NCV actuator is energized in a E3 injector, pressure rise is created in the EUI pump chamber. Who is correct?