What are two inherent factors that limit the amount of current used by a motor that is supplied from a DC source?

What will be an ideal response?


Two factors limit the amount of current used by a motor that is supplied from a DC source: (1) the counter-electromotor force (CEMF) produced in the rotor by the spinning of the conductors through a magnetic field and (2) the actual resistance of the motor windings.

Trades & Technology

You might also like to view...

Consider the word “wireless,” composed of eight symbols, each symbol being a letter of the English alphabet. This word is encrypted by first applying a permutation function and then a substitution function. The permutation function is applied on a 4 -symbol half word as follows: (1234) => 4132) —that is, every half word with input symbols 1234 is transformed to an output half word, which is 4132 . The word is interpreted as a sequence of two half words. The substitution function is as follows: