When is a heat exchanger classified as being compact? Do you think a double-pipe heat exchanger can be classified as a compact heat exchanger?

What will be an ideal response?


A heat exchanger is classified as being compact if ? > 700 m2/m3 or (200 ft2/ft3) where ? is the ratio of the heat transfer surface area to its volume which is called the area density. The area density for double-pipe heat exchanger can not be in the order of 700. Therefore, it can not be classified as a compact heat exchanger.