A patient who has been prescribed a bronchodilator via a metered-dose inhaler (MDI) has difficulty coordinating her breath with the actuation of the MDI. What should the therapist recommend for such a patient?
A. Use a valved holding chamber.
B. Practice the technique many times using the MDI.
C. Nebulize the drug with a small-volume nebulizer.
D. Use a dry powder inhaler.
?ANS: A
A. Correct response: Using either a spacer or a valved holding chamber eliminates the problem associated with coordinating the breath and the actuation of the MDI. The patient simply needs to dispense the contents of the MDI into either the spacer or valved holding chamber, then inhale the medication from the spacer or valved holding chamber.
B. Incorrect response: See explanation A.
C. Incorrect response: Using a small-volume nebulizer may not always be practical for the patient, especially if the patient is away from home. The patient may need quick relief from a bronchodilator while out shopping or at some social event. Again, a SVN would not be available or practical.
D. Incorrect response: The patient may be incapable of generating the high inspiratory flows (40 L/min to 60 L/min) that are required to effectively use a dry powder inhaler.
You might also like to view...
The person ultimately responsible for safety of the patient is the:
a. supervising PT. b. PTA providing interventions. c. PT aide preparing the environment. d. person with the patient.
Several collecting ducts merge to form papillary ducts, which then deliver urine to a minor calyx
Indicate whether the statement is true or false
Define hydrokinetics
What will be an ideal response?
The filament is on the negative side of the vacuum tube in the dental x-ray machine
Indicate whether the statement is true or false