REFRIGERANT

      TEMP
_____________________
TEMP
______________________
TEMP
________________________
°F
12
22
134a
502
°F
12
22
134a
502
°F
12
22
134a
502
               -60
19.0
12.0
 7.2
12
15.8
34.7
13.2
43.2
42
38.8
71.4
37.0
83.8
-55
17.3
9.2
 3.8
13
16.4
35.7
13.8
44.3
43
39.8
73.0
38.0
85.4
-50
15.4
6.2
 0.2
14
17.1
36.7
14.4
45.4
44
40.7
74.5
39.0
87.0
-45
13.3
2.7
 1.9
15
17.7
37.7
15.1
46.5
45
41.7
76.0
40.1
88.7
-40
11.0
0.5
14.7
4.1
16
18.4
38.7
15.7
47.7
46
42.6
77.6
41.1
90.4
-35
8.4
2.6
12.4
6.5
17
19.0
39.8
16.4
48.8
47
43.6
79.2
42.2
92.1
-30
5.5
4.9
9.7
9.2
18
19.7
40.8
17.1
50.0
48
44.6
80.8
43.3
93.9
-25
2.3
7.4
6.8
12.1
19
20.4
41.9
17.7
51.2
49
45.7
82.4
44.4
95.6
-20
0.6
10.1
3.6
15.3
20
21.0
43.0
18.4
52.4
50
46.7
84.0
45.5
97.4
-18
1.3
11.3
2.2
16.7
21
21.7
44.1
19.2
53.7
55
52.0
92.6
51.3
106.6
-16
2.0
12.5
0.7
18.1
22
22.4
45.3
19.9
54.9
60
57.7
101.6
57.3
116.4
-14
2.8
13.8
0.3
19.5
23
23.2
46.4
20.6
56.2
65
63.8
111.2
64.1
126.7
-12
3.6
15.1
1.2
21.0
24
23.9
47.6
21.4
57.5
70
70.2
121.4
71.2
137.6
-10
4.5
16.5
2.0
22.6
25
24.6
48.8
22.0
58.8
75
77.0
132.2
78.7
149.1
-8
5.4
17.9
2.8
24.2
26
25.4
49.9
22.9
60.1
80
84.2
143.6
86.8
161.2
-6
6.3
19.3
3.7
25.8
27
26.1
51.2
23.7
61.5
85
91.8
155.7
95.3
174.0
-4
7.2
20.8
4.6
27.5
28
26.9
52.4
24.5
62.8
90
99.8
168.4
104.4
187.4
-2
8.2
22.4
5.5
29.3
29
27.7
53.6
25.3
64.2
95
108.2
181.8
114.0
201.4
0
9.2
24.0
6.5
31.1
30
28.4
54.9
26.1
65.6
100
117.2
195.9
124.2
216.2
1
9.7
24.8
7.0
32.0
31
29.2
56.2
26.9
67.0
105
126.6
210.8
135.0
231.7
2
10.2
25.6
7.5
32.9
32
30.1
57.5
27.8
68.4
110
136.4
226.4
146.4
247.9
3
10.7
26.4
8.0
33.9
33
30.9
58.8
28.7
69.9
115
146.8
242.7
158.5
264.9
4
11.2
27.3
8.6
34.9
34
31.7
60.1
29.5
71.3
120
157.6
259.9
171.2
282.7
5
11.8
28.2
9.1
35.8
35
32.6
61.5
30.4
72.8
125
169.1
277.9
184.6
301.4
6
12.3
29.1
9.7
36.8
36
33.4
62.8
31.3
74.3
130
181.0
296.8
198.7
320.8
7
12.9
30.0
10.2
37.9
37
34.3
64.2
32.2
75.8
135
193.5
316.6
213.5
341.2
8
13.5
30.9
10.8
38.9
38
35.2
65.6
33.2
77.4
140
206.6
337.2
229.1
362.6
9
14.0
31.8
11.4
39.9
39
36.1
67.1
34.1
79.0
145
220.3
358.9
245.5
385.0
10
14.6
32.8
11.9
41.0
40
37.0
68.5
35.1
80.5
150
234.6
381.5
262.7
408.4
11
15.2
33.7
12.5
42.1
41
37.9
70.0
36.0
82.1
155
249.5
405.1
280.7
432.9
An R-22 cylinder containing enough refrigerant to have liquid refrigerant in it, is in a truck with a temperature of 120°F. What would be the psig pressure in the cylinder?

A. 255.7 psig
B. 259.9 psig
C. 267.0 psig
D. 271.5 psig


Answer: B

Trades & Technology

You might also like to view...

Telescopic-boom modes refer to which of the following?

a. The percentage and sequence in which the boom sections are extended b. Whether the boom is extended by cables or hydraulic actuators c. Whether the boom position is above or below the horizontal d. Whether the lift occurs from the main boom or a jib extension

Trades & Technology

¿Cuál es la carga de iluminación en un circuito de 120V para seis luces incandescentes de 100W y cuatro accesorios fluorescentes con una clasificación de balastos de 1,5A, todos con funcionamiento continuo de 8 horas por día?

a. 10,50A b. 11,20A c. 13,75A d. 15,60A

Trades & Technology

Which of the following is the coefficient of coupling between two coils?

A. M B. mH C. LT D. k

Trades & Technology

A rectifier is a component that converts AC to DC by allowing the current to be ____.

A. increased B. decreased C. removed D. all positive or all negative

Trades & Technology