Technician A says that when placing an inductive pick-up clamp onto a starter cable, the arrow must point to the correct direction of current flow. Technician B says that high current flow can be produced by an open in the starter motor field windings. Who is correct?
A. Technician A only
B. Technician B only
C. Both A and B
D. Neither A nor B
Answer: A
You might also like to view...
What is the difference between a Level 4 and a Level 5 programming system
What will be an ideal response?
______ breeding horses involves turning stallions into a field with mares and allowing mating to occur naturally.
A. Hand B. Pasture C. Passive D. Cross
Zone control is accomplished in hydronic systems using thermostats that activate
A) a zone control valve for each zone B) a zone compressor for each zone C) a zone boiler for each zone D) a zone damper for each zone
What is the CFM of air moving through an 8 in × 10 induct if the air velocity is 800 FPM?
A) 8 × 10 = 80 sq in, 80/144 = 0.56 sq ft, 800/0.56 = 1,428 CFM B) 8 × 10 = 80 sq in, 800/80 = 10 CFM C) 8 × 10 = 80 sq in, 80/144 = 0.56 sq ft, 800 × 0.56 = 444 CFM D) 800 CFM