What components are typically included in a fire-rated partition assembly which is designed for effective sound control and a high fire rating?

What will be an ideal response?


A typical assembly for a fire-rated partition designed to offer effective sound control and a high fire rating uses steel studs, gypsum lath on steel furring, a gypsum finish coat, and a sound attenuation blanket in the wall cavity.