Technician A says that battery cells requiring frequent topping up is an indicator of over-charging. Technician B says that voltage regulators should not be set above 14.1 volts on many current trucks. Who is correct?
A. Technician A only
B. Technician B only
C. Both A and B
D. Neither A nor B
Answer: C
You might also like to view...
Explain what pretensioning of concrete is.
What will be an ideal response?
What must the technician do before checking an air conditioning system for refrigerant leaks using a black light?
A) Evacuate the system B) Overcharge the system by 10 oz. C) Turn the system off and allow the pressure to equalize D) Install dye in the system
Discuss how the value of inductance and capacitance affects the frequency of resonance of a circuit.
What will be an ideal response?
Technician A says current will increase with a decrease in resistance. Technician B says current will decrease with an increase in resistance. Who is correct?
A. Technician A only B. Technician B only C. Both A and B D. Neither A nor B