Determine the joint clamp force (N) for a hot-dip galvanized M50 stud and hex nut combination that has been tightened to a torque value of 12,511 N-m.
What will be an ideal response?
The reference torque value may be calculated using: T = KDF
T = 12,511 N-m, K for hot-dip galvanizing = 0.25, Nominal D = 50mm or 0.05m, and F =? Some manipulation of the equation will yield T/(KD) = F; 12,511 N-m/(0.25 x 0.05m) = 1,000,849 N
You might also like to view...
What material is the Post Base made from?
Review drawing number 523690C0A and then answer the question.
The item in the following list that is not a use for interior trim is _____.
a. hiding joints at the intersection of floors, walls, ceilings, and different wall coverings b. protecting vulnerable edges c. enabling a door to swing freely in its frame d. holding window sashes in place
What type of measurement is a grain?
A) A grain is theoretically extrapolated by multiplying the cube root of the wet bulb measurement times the dry bulb temperature measurement B) A grain is a small measurement of weight C) A grain is equal to one drop of water D) A grain is a small measurement of volume
Regarding transistor operation in general:
A) a small base current controls a large collector current B) collector current controls base current C) a large base current controls a small collector current D) emitter current controls collector current