A biofuel subsidiary of Petrofac, Inc. is planning to borrow $12 million to acquire a small technology-based company. The rate on a 5-year loan is highly variable; it could be as low as 7%, as high as 15%, but is expected to be 10% per year. The company will only move forward with the acquisition offer if the AW is below $6.1 million. The M&O cost is fixed at $3.1 million per year. The anticipated sales price of the company could be $2 million if the interest rate is 7% or as much as $2.5 million if the rate is 15%, but will most likely be about $2.3 million at the 10% per year rate. Is the decision to move forward with the acquisition sensitive to the loan interest rate and salvage value estimates?
What will be an ideal response?
Required AW < $-6.1 million
7%: AW = -12,000,000(A/P,7%,5) – 3,100,000 + 2,000,000(A/F,7%,5)
= -12,000,000(0.24389) – 3,100,000 + 2,000,000(0.17389)
= $-5,678,907 (< $-6,100,000; acceptable)
10%: AW = -12,000,000(A/P,10%,5) – 3,100,000 + 2,300,000(A/F,10%,5)
= -12,000,000(0.26380) – 3,100,000 + 2,300,000(0.16380)
= $-5,888,836 (< $-6,100,000; acceptable)
15%: AW = -12,000,000(A/P,15%,5) – 3,100,000 + 2,500,000(A/F,15%,5)
= -12,000,000(0.29832) – 3,100,000 + 2,500,000(0.14832)
= $-6,309,040 (> $-6,100,000; not acceptable)
The decision is sensitive, since AW at 15% exceeds maximum of AW = $-6,100,000
You might also like to view...
It is acceptable to lay pilasters so that units must be cut.
Answer the following statement true (T) or false (F)
Name the concept that requires an increase in system temperature when the outdoor air temperature drops.
What will be an ideal response?
Most hydronic heating systems are
A) Open systems in cooling and closed systems in heating B) Closed piping systems C) Closed systems in cooling and open in heating D) Open piping systems
Which of the following statements does not describe objectionable current?
A. Neutral current flowing over the neutral grounding conductor B. Neutral current flowing over the equipment grounding conductor C. Neutral current flowing over cable shields D. Neutral current flowing over metal conduit