Referring to the following figure, technician A says that a loose connection at the left dash panel ground stud could prevent the low air lamp from illuminating and the audible alarm from sounding when air in the brake systems is low. Technician B says that an open circuit 11-GD could cause the low air lamp to illuminate. Who is correct?

A. A only
B. B only
C. Both A and B
D. Neither A nor B


Answer: A

Trades & Technology

You might also like to view...

A metal mortar pan is about _____ deep.

A. 4" B. 5" C. 7" D. 10"

Trades & Technology

Autogenous welds work best on flare, outside corner, and lap joints because as the metal is melted, it can more easily flow together than it would on butt and tee joints.

Answer the following statement true (T) or false (F)

Trades & Technology

Two loads connected in parallel draw a total of 2.4 kW at 0.8 lagging pf from a 120-V rms, 60-Hz line. One load absorbs 1.5 kW at a 0.707 lagging pf. Determine: (a) the pf of the second load, (b) the parallel element required to correct the pf to 0.9 lagging for the two loads.

What will be an ideal response?