Which type of valve operates on the principle that as the pressure in a cylinder increases, the temperature of the gas increases?
a. Direct-acting valves c. Rupture-disk pres-sure-relief valves
b. Fusible-plug pres-sure-relief valves d. Spring-loaded pressure-relief valves
ANS: B
Fusible-plug pressure-relief valves operate on the principle that as the pressure in a tank increases, the temperature of the gas increases, causing the plug to melt. Spring-loaded devices are de-signed to release excessive cylinder pressure and reseal, preventing further release of gas from the cylinder after the cause of the excessive pressure is removed. The rupture-disk will buckle when the pressure inside the cylinder exceeds a certain predetermined limit. Direct-acting valves are not pressure-relief valves; instead, they are controlling devices that seal the contents of a com-pressed cylinder until it is ready for use.
You might also like to view...
Prepare 1oz of epinephrine 0.025% solution by mixing epinephrine 0.5% and sterile water for injection. How much epinephrine 0.5% solution will be needed?
A) 1.5 mL B) 2.5 mL C) 22.5 mL D) 28.5 mL
__________________ deals with the number of admissions, discharges, transfers and number of patients under the care of a hospice on a given day.?
A) reimbursement data B) ?resource data C) patient data D) ?census data
At a fire, 6 sprinkler heads have opened. They are operating at a 30 psi pressure. What is the total discharge?