For a solar system located in Colorado, how many flat-panel solar collectors with dimensions of 1 m 1.5 m and an efficiency of 58% would be required to heat up 80 gallons of water from 65°F to 120°F during the month of January? State your assumptions.

What will be an ideal response?


Energy required to heat up 80 gallons of water from 65°F to 120°F is given by



The efficiency of the system is 58%, so the amount of energy required to intercept



Assuming 4 kWh/m2/day of solar radiation could strike the collectors that are tilted at an angle equal to the latitude of the location, the total required size of the flat solar panels is given as follows.



Considering the size of each panel is 1.5 m2, the number of the flat solar panels required



So, four (4) panels are required to heat up 80 gallons of water from 65°F to 120°F every day in January.

Environmental & Atmospheric Sciences

You might also like to view...

Clay sediments and shale generally have _____

a. high permeability and high porosity b. low permeability and low porosity c. high permeability and low porosity d. low permeability and high porosity e. no permeability and no porosity

Environmental & Atmospheric Sciences

Volcanoes and earthquakes are concentrated along the margins of lithospheric plates.

Answer the following statement true (T) or false (F)

Environmental & Atmospheric Sciences

Examine the image below before answering this question. D represents a magma chamber.Which relative time principle assumes that G is older than F?

A. Original horizontality B. Superposition C. Inclusions D. Cross-cutting

Environmental & Atmospheric Sciences

A 200-Hz tuning fork will resonate when it encounters a sound wave of frequency

A. 300 Hz. B. 200 Hz. C. 150 Hz. D. none of the above

Environmental & Atmospheric Sciences