A patient is on 80%/20% heliox therapy by nonrebreathing mask. If flowing through an oxygen flow meter, what is the actual flow of the mixture if the flow meter indicates 10 L/min?

A. 18 L/min
B. 8 L/min
C. 14 L/min
D. 16 L/min


A. 18 L/min
Explanation :
When helium-oxygen mixtures are run through flow meters that are intended for oxygen only, the indicated flow on the flow meter is inaccurate. This is because the helium-oxygen mixture is less viscous and does not push the indicator ball up as much as does oxygen. In this case, a correction factor must be used depending upon the mixture percentages. For an 80/20% mixture a correction factor of 1.8 must be used. A 70/30% mixture has a correction factor of 1.6 and a 60/40% mixture has a correction factor of 1.4. In this problem the 80/20% mixture factor of 1.8 must be multiplied by the indicated flow on the oxygen flow meter to calculate actual total gas flow. When we do this we get a total gas flow of 18 L/min.

Health Professions

You might also like to view...

The myopic eye requires a ________ lens to correct vision

a. concave b. convex c. congruent d. convoluted

Health Professions

Your patient was struck in the chest with a baseball bat during a bar fight. A crackling or crunching sensation that is felt when air escapes from its normal passageways and is trapped under the skin is called:

A) crepitus. B) friction rub. C) subcutaneous emphysema. D) infiltration.

Health Professions

Among the new skills that surgeons must learn is the loss of _________ feedback

A. haptic B. septic

Health Professions

Atrial flutter has an atrial rate

A) greater than 100. B) between 40 and 60. C) between 250 and 350. D) between 60 and 100.

Health Professions