A viscous type vibration damper shows trace fluid leakage. Which of the following is recommended?

A. seal with silicone
B. check with a balance sensor
C. repair weld the crack
D. replacement


Answer: D

Trades & Technology

You might also like to view...

Symbol E in Figure 2 represents a _____.

a. float switch b. temperature switch c. pressure switch d. foot switch

Trades & Technology

Cleanse and sanitize a customer's nail before applying artificial nails because:

What will be an ideal response?

Trades & Technology

In a capacitor-start, capacitor-run motor, the centrifugal switch disconnects a start capacitor and connects a run capacitor

Indicate whether the statement is true or false

Trades & Technology

A common practice in condensing units is to use a contactor with only one set of contacts opening only one side of the power to the unit. This is to ____.

A. reduce the cost of the contactor B. make it easier to wire the unit C. teach the service technician not to put hands in the unit with the power on D. provide off-cycle heat to the compressor