What would you suspect first, if a standard medium temperature reach-in with a fixed metering device had the following conditions:
? a condensing temperature 45° above ambient, HIGH
? 10° subcooling, NORMAL
? evaporator temperature 10° below the box temperature, HIGH
? and 0° superheat? LOW (Flooding)
a. dirty condenser b. dirty or iced evaporator c. low on charge d. restricted cap tube
a. dirty condenser