What types of problems could cause a TEV system to operate at too high a superheat?
What will be an ideal response?
System undercharge, liquid line refrigerant restriction, dead TEV power element, TEV plugged with debris from brazing
You might also like to view...
? Identify and state the historical significance ofSamuel Slater.
What will be an ideal response?
Field marking of service equipment shall include the _____.
a. time of installation b. date fault current calculations performed c. identification of phase wires d. location of disconnecting means
____________________ testing is used to determine how well a weld can resist repeated fluctuating stresses or cyclic loading.
Fill in the blank(s) with the appropriate word(s).
Technician A says that if a PCV valve rattles, then it is okay and does not need to be replaced. Technician B says that if a PCV valve does not rattle, it should be replaced. Which technician is correct?
A) Technician A only B) Technician B only C) Both technicians D) Neither technician