Which component of lubrication systems is a device that removes contaminants and particulates from the lubricant prior to circulation through a system?
A) Cooler
B) Filter
C) Pump
D) Lube oil reservoir tank
Answer: B
Explanation: A) Incorrect. A cooler is a device that removes heat from lubricant circulating through a system.
B) Correct. A filter is a device that removes contaminants and particulates from the lubricant prior to circulation through a system.
C) Incorrect. A pump is a device used to increase pressure in order to move the lubricant through a system to the process equipment, and back again.
D) Incorrect. A lube oil reservoir tank is a vessel that contains lubricating oil for a system.
You might also like to view...
Answer the following statement(s) true (T) or false (F)
1. A 3/4-inch pipe can handle a maximum load of 140,000 BTUH. 2. A reverse return system usually results in a longer total circuit length. 3. In a series loop system, the tubing in the baseboard is basically the pipe main. 4. In a two-pipe direct return system, all of the heating terminals are in parallel with each other. 5. When breaking a building into smaller areas (zones), the heat supplied to each area cannot be adjusted as the load fluctuates.
Investigate the R-factor of building insulation. What values did you find for 3-inch and 6-inch-thick insulation?
What will be an ideal response?
Overweight, oversized loads:
a. Require special permits. b. Can only be driven at daylight. c. Must be accompanied by the police.
When lifting loose materials such as pipe or bar stock, use a _____
a. chain and hook b. double-wrap choker hitch c. beam clamp d. hook in the banding