The transfer function of the second-order highpass filter is given by


a1 = 16154.0474, a0 = 1.304766×108
? 0 = a 0= 11422.6354 rad/s
The Q value is given by
Q = ? a1
0= 0.7071
The normalized component values are given by
C1 = 1 F, C2 = 1 F, R1 = 1 ?, R2 = 1 ?, RB = 1 ? , RA = 2 – 1/Q = 0.5858 ?
Application of the magnitude scaling (km = 1000) and frequency scaling (kf = ?0 = 11422.6354) yields
C1 = 1F
k m k× f
= 87.5455 nF
C2 = 1F
k m k× = 87.5455 nF
f
R1 = 1×1000 ? = 1 k?
R2 = 1×1000 ? = 1 k?
RB = 1×1000 ? = 1 k?
RA = 0.5858×1000 ? = 585.7863 ?