List six general requirements for power transmission and distribution
What will be an ideal response?
• All electrical equipment and lines should be considered energized it has been determined from tests or inspections that they are not.
• Operating voltage of all lines and equipment must be determined before beginning work so that the safe distance set forth in Figure 11-1 can be properly maintained.
• Lines and equipment must be disconnected from their sources of energy and the connector must be locked out before work begins.
• Workers must be trained in emergency procedures and first aid.
• Drown-proofing precautions must be taken when work is done over water.
• Sufficient lighting must be provided when work is done at night or in any setting that is dark.
You might also like to view...
Carbon steel trowels are preferred to stainless steel ones.
Answer the following statement true (T) or false (F)
Answer the following statements true (T) or false (F)
Like incremental snap, object snap will not interfere with ordinary point selection.
The CATV access network mimics that of traditional telephone access network?
Indicate whether the statement is true or false
Answer the following statement(s) true (T) or false (F)
1. Nonlinear equations, such as those for the power flow, can have multiple solutions. 2. Because of line resistance, the power flow Jacobian matrix is guaranteed to never be singular. 3. In the power flow the voltage angle at the slack bus does not change. 4. The dc power flow solves for the per unit voltage magnitudes,assuming that the voltage angles are constant at zero degrees. 5. When solving a minimization problem adding contraints will result in a cost function value that is greater than or equal to that of the unconstrained problem.