Match the description of each step used in the calibration process with the proper sequence of steps.
A. Step 1
B. Step 2
C. Step 3
D. Step 4
E. Step 5
A. Determine the full range of the variable being measured.
B. Select an appropriate sensor for the application and then determine the type of analog output signal produced by its transmitter.
C. Make a zero adjustment which causes the minimum analog output of the transmitter to be generated when the minimum value of the variable is measured.
D. Make a span adjustment which causes the maximum output of the transmitter to be generated when the maximum value of the variable is measured.
E. Verify that the zero and span adjustments are accurate when the minimum and maximum values of the variable are measured.
You might also like to view...
What is the breed of cattle that ranks first in average milk production per cow?
a. Jersey c. Guernsey b. Holstein d. Brown Swiss
Nurseries that produce plants in accordance with the performance standards established by their state nursery associations are legally ____________________
Fill in the blank(s) with correct word
In the Root-Takahira agreement of 1908
A. the Japanese government agreed to limit the number of Japanese immigrant laborers entering the United States. B. the United States and Japan agreed to respect each other's territorial holdings in the Pacific. C. the United States agreed to accept a Japanese sphere of influence in China. D. Japan agreed to accept U.S. control of the Philippines in exchange for Japanese domination of Manchuria. E. None of these choices are correct.
As additional branches are added to a a parallel circuit, total circuit resistance _______
A) Remains the same B) Decreases C) Increases D) None of these