During an AC performance test, an R-134a air conditioning system has a measured center duct outlet temperature of 59 degrees F. A manifold gage set shows low side pressure ranges between 40-55 psi and the high side pressure ranges from 275-375 psi. Shop temperature is 72 degrees F. What is most likely the cause?

a. The TXV is restricted and not allowing sufficient refrigerant to flow
b. The system has a low refrierant charge
c. The compressor is defective
d. The system is overcharged


D. The system is overcharged

Trades & Technology

You might also like to view...

What is a rectangular array? What is a polar array?

What will be an ideal response?

Trades & Technology

This problem concerns a compound which, in the vapor phase, is described by the equation of state:

PV = RT + (BP3) Where B = 0.005 L mol-1atm-2 In the liquid phase, the molar volume is constant at 0.150 L/mol. The vapor pressure can be modeled using the Antoine equation, with A=7.500, B=1400, C=225, temperature expressed in Celsius and pressure expressed in mm Hg. A) Derive an algebraic expression for the fugacity of the compound in the vapor phase, as a function of temperature and pressure. B) Use the Antoine equation to estimate the vapor pressure at 200 ?C. C) Estimate the fugacity of the compound in the liquid phase at 200 ?C and 100 atm.