The following two graphic loops show which of the following conditions?

a. Leak in the patient-ventilator circuit
b. Increased airway resistance
c. Decreased lung compliance
d. Active exhalation


ANS: A
Because the expiratory volume does not return to zero in these graphics, a leak is present in the patient-ventilator circuit. Increased airway resistance would show as a scooped-out expiratory flow on the flow-volume loop, which may not end before the next breath. Decreased lung com-pliance would show as a "duck bill" on the pressure-volume loop. Active exhalation would make the volume tracing drop below zero.

Health Professions

You might also like to view...

The dental dam that slides between the teeth is called the septum

a. True b. False Indicate whether the statement is true or false

Health Professions

Which cartridge has a yellow band in the required ADA color-coding system?

A) 3% mepivacaine, 1:20,000 levonordefrin B) .5% bupicavaine, 1:200,000 epinephrine C) 4% articaine, 1:100,000 epinephrine D) 4% prilocaine, 1:200,000 epinephrine

Health Professions

When a patient needs transport to a hospital, you may leave the scene after you verify that an ambulance will arrive within five minutes

Indicate whether the statement is true or false

Health Professions

The most common adverse reaction to penicillin is

a. headache. b. nausea. c. allergic reaction. d. seizures.