Place the following noncondensing steam turbine startup procedures in order.
____ Verify the lube oil and cooling water are in service.
____ Communicate with the team that the turbine is ready.
____ Open turbine case drains.
____ Slow roll the steam turbine.
____Observe the steam coming out of the drains and, when it becomes dry, completely open the low-pressure steam valve and close the drain valve.
____ Unblock the high-pressure steam.
____ Ensure that the driven equipment connected to the steam turbine is ready for startup.
____ Adjust turbine speed as needed.
____ Open the low-pressure steam valve slightly
1. Open turbine case drains.
2. Open the low-pressure steam valve slightly
3. Observe the steam coming out of the drains and, when it becomes dry, completely open the low-pressure steam valve and close the drain valve.
4. Ensure that the driven equipment connected to the steam turbine is ready for startup.
5. Verify the lube oil and cooling water are in service.
6. Slow roll the steam turbine.
7. Communicate with the team that the turbine is ready.
8. Unblock the high-pressure steam.
9. Adjust turbine speed as needed.
You might also like to view...
Boiler water temperature is typically controlled by a(n) _____.
a. aquastat b. thermostat c. limit switch d. bi-metal disc
The cooling basin temperature is:
a. 60ºF b. 75ºF c. 85ºF d. 100ºF
What is the relative humidity if the dry-bulb temperature is 100º F and the wet-bulb temperature is 65°F?
A. 13%. B. 28%. C. 43%. D. 58%.
What is the function of the wiring diagram?
What will be an ideal response?