During assist-control ventilation with flow as the control variable, identify the variable responsible for cycling

A. time
B. pressure
C. volume
D. flow


?ANS: C
A. Incorrect response: See explanation C.
B. Incorrect response: See explanation C.
C. Correct response: The cycle variable is the variable responsible for the termination of inspiration. During assist-control ventilation, the control variable is flow, and when the preset volume is reached, the ventilation cycles, that is, inspirations ends and expiration begins. The variable for terminating inspiration in this instance for volume-control ventilation is volume. Therefore volume is the cycle variable.
D. Incorrect response: See explanation C.

Health Professions

You might also like to view...

Which of the following is NOT a legal implication to consider when treating a minor?

a. Minor's medical knowledge b. Right to confidentiality c. Financial responsibility d. Minor's legal guardian

Health Professions

Opioid analgesics are most effective in treating

a. Thalamic pain b. Central pain c. Neuropathic pain d. Nociceptive pain

Health Professions

____ is information about content. For example, a radiologic image (content) can be described by patient, date, time, and so on.

A. Metadata B. Symbolic data C. Internal data D. Raw data

Health Professions

Before attaching a transcutaneous blood gas monitor sensor to a patient, what should you do?

1. Provide a specified warm-up time and set the probe temperature. 2. Check the membrane and prepare a sensor with an adhesive ring and gel. 3. Prepare the monitoring site (remove excess hair and clean the skin). a. 1 and 2 only b. 1 and 3 only c. 2 and 3 only d. 1, 2, and 3

Health Professions