What effect would a low-side restriction have on a system and how would it be detected?
What will be an ideal response?
A restriction on the low-side of the refrigerant system is not as likely due to the larger diameter of the lines and hoses. But it is still possible for restrictions to occur in the evaporator core if the system is contaminated, and if the system has an accumulator the desiccant may have failed. If a low-side restriction occurs the low side gauge reading will be low or even a vacuum depending on where the service fitting is located in relation to the restriction. If the compressor is not able to circulate the refrigerant due to the low side restriction the high-side gauge reading will also be low. Finding the restriction by looking for temperature differentials before and after the low -side restriction is still possible but the temperature differential on either side will not be as great and some temperature difference between the evaporator inlet and outlet is expected.
You might also like to view...
Ethics of care does not tell us how we are to determine what will help or harm particular individuals
Indicate whether the statement is true or false
Evaluate the following analogical argument:He: Let's leave Cincinnati for the golden West! Why don't we move to Los Angeles?She: Well, for one thing, we couldn't afford to buy a house there.He: Don't be such a pessimist. We bought this house here, didn't we? How much more expensive can houses in Los Angeles be?
What will be an ideal response?
According to Epictetus, a well-cultivated will is the source of happiness
Indicate whether the statement is true or false
If the experimentalist method were followed, then ethical norms would be treated as hypotheses, which need to be tested and confirmed
Indicate whether the statement is true or false