How does air from air-conditioning vents affect open display cases?
A) Open display cases are not affected by external air sources because of their powerful built-in air curtains.
B) Open display cases are not affected by external air sources because of their engineered air baffles.
C) It improves their performance by lowering the temperature of the air surrounding the display case.
D) It disrupts the case's air curtain, causing them to rise in temperature.
D
You might also like to view...
Ultrasound can be used by producers to measure the quality of meat in live hogs
Indicate whether the statement is true or false.
In the decision-making process, managers choose the ``best’’ alternative from among a set
What does the term ``best’’ imply in this instance?
a. Efficiency b. Effectiveness c. An operational approach d. A quantitative approach e. A behavioral approach
What would you suspect first, if a standard medium temperature reach-in with a fixed metering device had the following conditions:
? a condensing temperature 45° above ambient, HIGH ? 10° subcooling, NORMAL ? evaporator temperature 10° below the box temperature, HIGH ? and 0° superheat? LOW (Flooding) a. dirty condenser b. dirty or iced evaporator c. low on charge d. restricted cap tube